Article in Portuguese | LILACS | ID: lil-725986

ABSTRACT

Objetivo: Correlacionar medidas lineares entre radiografias panorâmicas digitais (DPan) e tomografias computadorizadas cone beam (TCcb) na região do seio maxilar. Método: Foram selecionados exames aos pares de 71 sítios, 37 do lado direito e 34 do lado esquerdo, das radiografias panorâmicas digitais e suas correspondentes tomografias computadorizadas cone beam. As radiografias panorâmicas foram obtidas por meio do aparelhoOrthopantomograph® e foram analisadas por meio do software Image Tool v.3.0. As tomografias computadorizadas cone beam foram obtidas pelo tomógrafo i-CAT e analisadas pelo software Dental Slice. As mensurações foram realizadas por medidas lineares da distância da cortical inferior do seio maxilar até a cúspide incisal mais pronunciada do molar. Resultados: A comparação entre medidas apresentou concordância moderada e os valores foram estatisticamente (p<0,05) maiores nas medições da radiografia panorâmica digital compensada, com ampliação de 1,75 a 2,15 mm (8 a 9%), do que as medidas na tomografia computadorizada cone beam. Conclusão: Conclui-se que há necessidade de adicionar margem de segurança de 2,5 mm (10,5%) na região do seio maxilar, após a compensação da magnificação da imagem, quando for utilizada a radiografia panorâmica para planejamento cirúrgico para implantes dentários...


Objective: To correlate linear measurements between digital panoramic radiographs (DPan) and cone beam computed tomography images (CBCT) of the maxillary sinus area. Method: Seventy-one paired site exams were selected, 37 from the right side and 34 from the left side, on digital panoramic radiographs and their corresponding CBCT images. The panoramic radiographs were obtained by the Orthopantomograph®evice and analyzed by the Image Tool v.3.0 software. The CBCT images were obtained by the i-CAT tomograph and analyzed by the Dental Slice software. Linear measurements of the distance between the lower cortical of the maxillary sinus to the sharpest molar cusp. Results: Comparison of the measurements revealed a moderate agreement and the values were significantly higher in the measurements on the compensated digital panoramic radiographs (p<0.05) with 1.75 to 2.15 mm (8 to 9%) magnification, compared with the CBCT images.Conclusion: It may be concluded that when panoramic radiographs are used in the surgical planning for dental implants, a safety margin of 2.5 mm (10.5%) should be added in the maxillary sinus area after compensating for image magnification...


Subject(s)
Humans , Male , Female , Adolescent , Middle Aged , Young Adult , Radiography, Panoramic/instrumentation , Maxillary Sinus , Cone-Beam Computed Tomography/instrumentation , Data Interpretation, Statistical , Software
SELECTION OF CITATIONS
SEARCH DETAIL